Base Command Manager / Bright Cluster Manager Release Notes

Release notes for Bright 6.0-37

== cmdaemon ==

* Added: AdvancedConfig MaxAutoDetectDisks defaulting to 50: If the number of disks is above this value, no monitoring data will be saved for any disk related metric
* Improved: negative range syntax in cmsh for excluding nodes. Examples: node001..node100,-node040..node060,node050..node051, or node[001-100],-node0[40-60],node05[0-1]
* Improved: stride syntax in cmsh, e.g. odd nodes: node[001-100:2], or exclude every forth node: node[001-100],-node[004-100:4]
* Improved: automatically exclude CIFS and ceph filesystems during node updates
* Fixed: permissions issue in slapd.conf

== node-installer ==

* Changed HP iLO user configuration: set user ADMIN_PRIV to yes, when adding or modifying iLO user settings.
* Disk clone during failover setup now ignores multipath devices.

== node-installer-slave ==

* cm-clone-install: write cloneconfig in all cases, this was not being generated during normal clone

== cmgui ==

* Improved: play/pause button behavior for graphs
* Fixed: 'save as' not replacing existing file in monitoring window

== cuda-driver ==

* Update driver to version 319.72.

== intel-cluster-checker ==

* Update to version 2.1.1.

== intel-compilers-2013 ==

* Updated: composerxe version to 2013_sp1.1.106.

== intel-tbb ==

* Update to version 42_20131003oss.
* Changed environment modules to use prepend-path instead of append-path.

== modules ==

* Added: post script for env-modules-slave package, which creates current link for software images.